PTO and Pump Electrical Controls 54.38 Troubleshooting PTO and Fire Pump Controls Electrical Troubleshooting Table 4 : PTO Interlocks by Reference Param- eter Table 5 : Fire Pump Control Interlocks by Ref- erence Parameter Use Table 1 or Table 2 to begin troubleshooting. For power takeoff (PTO) function electrical diagnosis, see Table 1 . For fire pump controls function diagnosis, see Table 2 . Table 6 : PTO and Fire Pump Control J1587 Fault Codes Table 7 : PTO and Fire Pump Control J1939 Fault Codes Additional tables included in this subject are: Table 3 : PTO and Fire Pump Control Switch and Interlocks Test PTO Function Electrical Diagnosis Test No.
Test Procedure Test Result Action 1 In ServiceLink ® , use the Chassis Module (CHM) Configuration screen to determine which CHM solenoid output number controls the solenoid for the PTO. Go to test no. 2. Then open the "AMU Solenoids Circuits" or "AAVA Solenoids Circuits" in the appropriate Datalink Monitor template. Yes Make sure the vehicle has full air pressure. Turn the ignition on. Perform the PTO and Fire Pump Control Switch and Interlocks Test in Table 3. Attempt to engage the PTO using the smart switch in the dash while observing the status of the solenoid output under the "Outputs from BHM" heading for the solenoid number determined above. See Fig. 1 and Fig. 3.
No Does the output status turn on at all? It may turn on, then drop out. 2 Using the appropriate solenoids Datalink Monitor template, enter Test Mode. Go to test no. 3. Attempt to turn the PTO solenoid on using the ON button on the template. Yes Go to test no. 5. NOTE: When done, exit Test Mode. No When you attempt to turn on the PTO solenoid, can you hear it click? 3 Make sure the vehicle has full air pressure. Turn the ignition on. Yes Go to test no. 4.
Using the appropriate solenoids Datalink Monitor template, attempt to engage the PTO using the smart switch in the dash while observing the status of the pressure switch under the "Inputs to BHM" heading for the solenoid number that controls the PTO. See Fig. 2 and Fig. 3. Check PTO solenoid pressure switch feedback circuit. Check the solenoid pressure switch. See Section 42.19. No Check if air line is connected to solenoid. Does the status of the pressure switch say AIR ON at all, even if it comes on, then goes off? If the above items are OK, replace CHM. Business Class M2 Workshop Manual, Supplement 22, September 2012 300/1