mercedes-benz — Mercedes-Benz Automated-Manual Transmissions Troubleshooting Guide

PTO and Pump Electrical Controls 54.38 Specifications AMU/AAVA Solenoid 1 Smart Switch 399A Pressure Feedback Switch J1939 399 Chassis Module Bulkhead Module Solenoid Coil PUMP AMU/AAVA Solenoid 2 399C Pressure Feedback Switch 399B Solenoid Coil 02/22/2012 f544724 NOTES: Pump functions require two solenoids to shift the transfer case. Solenoid 1 provides air when power is applied to the solenoid coil (normally closed). Solenoid 2 provides air when power is removed from the solenoid coil (normally open). The pressure switch closes when air pressure reaches about 12 to 28 psi (83 to 193 kPa).

Only the feedback from the pressure switch in the normally closed solenoid is used by the pump control system. The other circuit is wired, but is not used. Fig. 4, Typical Wiring Diagram of a Split Shaft PTO Business Class M2 Workshop Manual, Supplement 22, September 2012 400/3