Optional Power Switches and Connection 54.39 Optional Switch Connections Connecting to One Switch With a Junction Block 7. Using capscrews, attach the junction block cover to the junction block. 8. Connect the batteries or turn the battery discon- nect switch to the on position. 1. Turn off the engine, apply the parking brakes, and chock the tires. 2. Disconnect the negative leads from the batteries or, if the vehicle is equipped with a battery dis- connect switch, turn the switch to the off position. 9. Verify the operation of the circuit(s) connected to the red wire in the junction block. The optional switch should control the electrical feature(s) connected to the red wire. 3.
Locate the junction block attached to the frame rail near the Chassis Module (CHM.) See Fig. 1 . 10. Remove the chocks from the tires. Connecting to One Switch Without a Junction Block or Multiple Switches 1 2 3 1. Turn off the engine, apply the parking brakes, and chock the tires. 2. Disconnect the negative leads from the batteries or, if the vehicle is equipped with a battery dis- connect switch, turn the switch to the off position. 3. Locate the customer connection end of the optional-switch output circuit. The connection end of the output circuit is located on the chassis be- hind the cab. The circuit end is an exposed blunt-cut wire sealed with heat shrink.
There will be a blunt-cut circuit for each optional switch. See Fig. 2 . 11/16/2005 f544657 1. Junction Block Cover 2. Junction Block 3. Chassis Module Fig. 1, Junction Block 4. Use the identification label that is taped to the blunt-cut end to properly match the correct circuit with the corresponding optional switch. NOTE: The following method of splicing the optional-switch circuits to load circuits is ap- proved by Freightliner. Use solder splice repair kit ESY ES66 404, which works for 14 and 16 gauge wire. 4. Remove the capscrews that attach the junction block cover to the junction block, and remove the cover. 5. Locate the red wire in the junction block.
The red wire receives power from the output circuit of the optional switch. IMPORTANT: The power distribution module (PDM) fuse supplying power to the optional switch is rated for 15 amps. Do not exceed a combined current load of 15 amps at the red wire in the junction block . 5. Remove the heat shrink by cutting the optional- switch circuit wire near the end of the heat shrink. 6. Strip the insulation 3/8 to 1/2 inch (10 to 13 mm) from the ends of the optional-switch circuit wire and the wire for the load. 6. Connect to the red wire in the junction block using a #10 ring terminal. The optional switch can provide 15 amps of fused battery power at the red wire. 7.
Place the three-inch (76-mm) length of heat shrink from the repair kit over the circuit that is being spliced to the optional-switch circuit. 8. Place the solder sleeve from the repair kit over one of the stripped wires. Business Class M2 Workshop Manual, Supplement 10, September 2006 100/1