Cab Heater and Air Conditioner, Valeo 83.00 Troubleshooting Evaporator Probe Circuit Tests Test Conditions Test Point Good Result What to Do if Test Fails evaporator temperature probe key off, engine off Measure across pins on the temperature probe. for pre- 1-8-07: 16,000 to 16,730 Ω at 32°F (0°C) Replace temperature probe. sensor probe removed and disconnected fill a cup with ice then add water to make an ice-water bath NOTE:
use mostly ice and allow time for temperature to stabilize at 32°F (0°C) place the tip of the evaporator probe in the ice-water bath for 5 minutes before testing—leave the tip immersed while taking the resistance measurement—be sure the meter reading is stable before noting the final measurement for 1-8-07 on: 8910 to 9090 Ω at 32°F (0°C) evaporator temperature probe circuit test battery switch on (if equipped) key on, engine off Measure across temperature probe connector terminals. 5V Check for an open in circuits 338K and 338GP. sensor probe installed, but connector is disconnected If wiring is okay, replace the control head.
Table 9, Evaporator Probe Circuit Tests A/C Clutch Circuit Tests for Diagnosing No A/C Clutch Engagement software versions. With BHM software version 6.1, the total A/C clutch cycle time (on + off time) is a minimum of 15 seconds. This ensures that the A/C compressor does not cycle more than 4 times per minute. With BHM software versions 6.4 and 6.5, the minimum compressor off time is 15 seconds. This means the total cycle time (on + off time) will always exceed 15 seconds. This too, ensures that the A/C com- pressor does not cycle more than 4 times per minute. The A/C compressor clutch is controlled by the con- trol head (climate control panel).
When the control head determines that the A/C compressor is re- quired, it grounds the A/C request input to the bulk- head module (BHM). When the BHM receives the A/C request signal from the climate control panel, it will apply power to the A/C clutch output when the following conditions are met— engine has been running more than 5 seconds; The BHM sends power to energize the A/C clutch. A binary switch is wired into this circuit, which will pre- vent the compressor clutch from engaging if the re- frigerant pressure is too high or too low.
battery voltage is greater than 9.25V; low air pressure warning is not active on the ICU; When all of the following conditions are met, the control head will send the A/C request signal to the bulkhead module: A/C clutch has not been engaged in the previ- ous 15 seconds. NOTE: The A/C clutch cycle timer strategy is implemented differently, depending on BHM The air selection switch is in one of the A/C or defrost settings, or the recirculation mode is on. Business Class M2 Workshop Manual, Supplement 13, March 2008 300/15