Cab Heater and Air Conditioner, Valeo 83.00 Troubleshooting Backlighting Circuit Tests Test Conditions Test Point Good Result What to Do if Test Fails backlighting power test battery switch on (if equipped) Measure voltage between pins A2 (positive lead) and B8 (negative lead) on the control head connector while toggling the dimmer switch between full dim and full bright. voltage should be about 1.2V at full dim and 10.8V at full bright Check circuit 29A for an open/ short. key off, engine off If okay, refer to Group 54 for further diagnosis.
control head connector disconnected headlight switch on backlighting pulse width modulated (PWM) signal test battery switch on (if equipped) Measure frequency between pins A2 and B8 on the control head connector. 400 Hz Check circuit 29A for an open/ short. key off, engine off control head connector disconnected If okay, refer to Group 54 for further diagnosis. headlight switch on * The voltage should be approximately the same as the battery voltage. Table 11, Backlighting Circuit Tests J1587 Fault Codes, HVAC (bulkhead module related) MID 164 MID SID FMI Fault Description Action 164 057 05 A/C clutch output open circuit (low current) Check circuit 98A for an open circuit.
Check binary switch; it may be open. If open, check for low or high refrigerant pressure. Also check the switch itself. Check A/C clutch coil for an open circuit. 06 A/C clutch output shorted to ground (high current) Check circuit 98A for a short to ground. Table 12, J1587 Fault Codes, HVAC (bulkhead module related) MID 164 SA SPGN FMI Fault Description Action J1939 Fault Codes, HVAC (bulkhead module related) Source Address (SA) 33 33 1550 05 A/C clutch output open circuit (low current) Check circuit 98A for an open circuit. Check binary switch; it may be open. If open, check for low or high refrigerant pressure. Also check the switch itself. Check A/C clutch coil for an open circuit.
06 A/C clutch output shorted to ground (high current) Check circuit 98A for a short to ground. Table 13, J1939 Fault Codes, HVAC (bulkhead module related) Source Address (SA) 33 Business Class M2 Workshop Manual, Supplement 13, March 2008 300/18