Meritor WABCO Hydraulic Antilock Braking System (ABS) 42.26 Troubleshooting J1587 Fault 136-054 Recirculation Pump MID SID FMI Problem Test Test Result Action Recirculation pump on without being activated by ECU 1. Remove the black X2 connector from the ECU. With the ignition ON, measure the voltage between Pin 10 and a good chassis ground. Voltage zero Check the ECU and verify the fault. NOTE: In this case the ECU is sensing voltage on the pump monitor circuit (Pin 10 of the black X2 connector) when the pump relay was not activated by the ECU (Pin 6 of the black X2 connector). Voltage not zero Go to Test 2. 136 054 03 Voltage zero Check the ABS pump relay R17; it may be sticking or shorted.
2. Remove the ABS pump relay (R17) and repeat Test 1. Check for a short to power in Circuit 376B causing the pump to run when it should not be. Repair as necessary. Voltage not zero Recirculation pump does not switch on when activated by the ECU 3. Remove the black X2 connector from the ECU. With the ignition ON, link Pins 6 and 3 while measuring the voltage between Pin 10 and a good chassis ground. The pump should run (do not hold for more than 1 minute). Check for intermittent connections in Circuit 376B and check the ABS pump relay for intermittent operation. Repair as necessary. NOTE:
In this case the ECU does not sense voltage on the pump monitor circuit (Pin 10 of the black X2 ECU connector) when the pump relay was activated by the ECU (Pin 6 of the black X2 ECU connector). Voltage between 9.5 and 14 volts 136 054 04 Voltage below 9.5 or above 14 volts Check Circuit 376A and check Relay R17. Repair as necessary. Recirculation pump sticks or is locked 4. Remove the black X2 connector from the ECU. With the ignition ON, momentarily link Pins 6 and 3. The pump should run (do not hold for more than 1 minute). Pump runs Repeat the test to verify. If the fault persists, suspect a problem with the ECU. NOTE:
In this case, the ECU senses high current on the pump monitor circuit (Pin 10 of the black X2 ECU connector) indicating the pump motor is locked. 136 054 07 Pump does not run Replace the recirculation pump. Table 20, J1587 Fault 136-054 Recirculation Pump Business Class M2 Workshop Manual, Supplement 4, March 2003 300/26