mercedes-benz — Mercedes-Benz Automated-Manual Transmissions Troubleshooting Guide

Meritor WABCO Hydraulic Antilock Braking System (ABS) 42.26 Troubleshooting J1587 Fault 136-055 ECU MID SID FMI Problem Test Test Result Action 1. With the ignition OFF, measure the voltage between Pin 2 of the gray X1 ECU connector (Circuit GND) and a good chassis ground. Voltage zero volts Go to Test 2. Voltage not zero volts Check the ground circuit for a short to positive voltage. 136 055 02 Reference to ground interrupted Check the ECU ground circuit (GND) for an intermittent or loose connection. Check ground Splice S10. If the problem persists, suspect the ECU is at fault. Resistance near zero ohms 2.

Measure the resistance between Pin 2 of the gray X1 ECU connector and a good chassis ground. Resistance above zero ohms Check the ECU ground circuit (GND). Repair as necessary. Table 21, J1587 Fault 136-055 ECU J1587 Fault 136-251 Low Voltage MID SID FMI Problem Test Test Result Action Check the electrical system. If the problem persists, suspect the ECU is at fault. Voltage too high 1. Disconnect the black X2 ECU connector. Start the engine and run it at governed speed while measuring the voltage between Pins 3 and 9. Voltage between 9.5 and 14 volts 136 251 03 NOTE: Voltage to the ABS ECU must be between 9.5 and 14 volts to function properly.

Voltage below 9.5 or above 14 volts Check the batteries and charging system for malfunction. Repair as necessary. Verify that the batteries were not drained or the charging system was not overloaded when the fault occurred. If the problem persists, suspect the ECU is at fault. Low voltage to ABS solenoid valves 2. Disconnect the black X2 ECU connector. Start the engine and run it at idle while measuring the voltage between Pins 3 and 9 of the black X2 ECU connector. Voltage between 9.5 and 14 volts NOTE: Voltage to the ABS ECU must be between 9.5 and 14 volts to function properly. 136 251 04 Voltage below 9.5 or above 14 volts Check the batteries and charging system for malfunction.

Repair as necessary. Table 22, J1587 Fault 136-251 Low Voltage Business Class M2 Workshop Manual, Supplement 4, March 2003 300/27