daewoo Solar 140LC-V — Change Pilot Filter

CHANGE PILOT FILTER NOTE: Change pilot filter after first 250 hours of operation or rebuild, and every 500 hours thereafter. WARNING! The hydraulic oil will be hot after normal machine operation. Allow the system to cool down before changing pilot filter. Figure 54 1. Position the machine on the firm, level ground. Lower the front attachment to the ground and shut down engine. 2. Loosen the air breather cap slightly to release the internal pressure. 3. Locate pilot system filter assembly. See Figure 54. 4. Unscrew canister (5, Figure 55) and remove O-ring (3) and filter cartridge (4). NOTE: The canister will be filled with oil. Use caution when removing this assembly. 5.

Insert a new filter cartridge and O-ring. Apply a small amount of oil around the entire O-ring and reinstall the canister assembly onto the filter head (1, Figure 55). 6. After changing pilot filter, vent air from pump and check level of hydraulic oil tank. HAOC480L Figure 55 022-00058E Operation and Maintenance Manual Inspection, Maintenance and Adjustment 4-33