daewoo Solar 140LC-V — Replace Full Flow Hydraulic Oil Filter

REPLACE FULL FLOW HYDRAULIC OIL FILTER NOTE: Change full flow hydraulic oil filter after first 250 hours of operation or rebuild, and every 500 hours thereafter. WARNING! The hydraulic oil will be hot after normal machine operation. Allow the system to cool before attempting to service any of the hydraulic components. The hydraulic tank is pressurized. Loosen the hydraulic air breather cap slightly to allow the pressurized air to vent. After the pressure has been released, it is safe to remove either the fill cap or service covers or drain water from the tank. IMPORTANT Make sure to clean any dirt or water from the top of the hydraulic tank, especially around the fill port and filter ports.

1. Position the machine on firm, level ground. Lower the front attachment to the ground and shut down engine. 2. Loosen the air breather cap slightly to release the internal pressure. 3. Remove bolts (1, Figure 53) and service cover (2). Remove spring (3), valve (4) and O-ring (5) from filter (6). 4. Remove filter and properly discard. 5. Install new filter and a new O-ring. Install valve and spring. Install service cover plate. 6. Run engine for 10 minutes at low idle to purge air from circuit. 7. Shut down engine. 8. Check level in hydraulic oil tank. Add oil if necessary. HAOC460P Figure 53 4-32 Inspection, Maintenance and Adjustment 022-00058E Operation and Maintenance Manual