4. Remove breather/fill cap (2, Figure 69) and add oil to "H" mark on dipstick (1, Figure 69 ) CHANGE OIL IN TRAVEL REDUCTION DEVICE (ONE ON EACH SIDE OF UNIT) Figure 69 WARNING! The gear oil is very hot after the machine has been operating. Shut all systems down and allow them to cool. Before fully removing any motor case, inspection port plug, etc., loosen the plug slightly to allow pressurized air to escape. Figure 70 NOTE: Drain oil after first 250 hours of operation or rebuild, and every 1,000 hours thereafter. 1. Park machine on firm, level ground. 2. Rotate the track until ports (1 and 2, Figure 70) are in their proper positions as shown. 3.
Place a container under drain plug (2, Figure 70) and remove plugs (1 and 2) to drain the travel motor fluid. NOTE: Dispose of drained fluids according to local regulation. 4. Install drain plug (2, Figure 70). Refill the travel motor case with fluid through fill port (1) until the fluid level is at port. Install level and fill plug (1). NOTE: See “Fluid Capacities” on page 4-7. for capacity. 5. Repeat this procedure on the other travel motor. 4-40 Inspection, Maintenance and Adjustment 022-00058E Operation and Maintenance Manual