42 Operation Section Engine Starting When the ether switch is placed in the automatic mode, the ether injection system operates automatically, when the engine is cranking. The automatic mode is enabled if the engine has been idling for less than 10 seconds, if the engine speed is less than 200 rpm above low idle, if the ambient air temperature is below 0 C (32 F), and if the coolant temperature is below 0 (32 F). DO NOT USE ETHER (starting fluids) unless specifically instructed to do so. If the engine is equipped with an Air Inlet Heater (electrically or fuel ignited manifold heater), DO NOT use ether (starting fluids) at any time.

The use could result in engine damage and/or personal injury. Additional injections may be necessary in order to start the engine. Additional injections may be necessary in order to achieve the low idle speed. For additional information on the Ether Injection System refer to Troubleshooting Manual, “Air Inlet Heater Circuit - Test”. NOTICE The optional automatic ether injection system is the only starting fluid system that is recommended. Ex- cessive starting fluid can cause piston and ring dam- age. Use starting fluid for cold starting purposes only.

Starting Problems Startability will be improved at temperatures below 0 C (32 F) by the use of a continuous flow injection system and/or a jacket water heater. This will help alleviate white smoke and misfire during start-up in cold weather. Consult your Caterpillar dealer for other means of improving startability in cold temperatures. An occasional starting problem may be caused by one of the following items: Low battery charge Lack of fuel The Continuous Flow Ether is an optional ether starting aid that is available for use with the engine. The system injects ether into the air inlet manifold after the air inlet heater.

Extensive damage to the engine could occur if ether is directed at the air inlet heater during activation. Problem with the wiring harness If the engine fuel system has been run dry, fill the fuel tank and prime the fuel system. Refer to the Operation and Maintenance Manual, “Fuel System - Prime” topic (Maintenance Section). Continuous Flow Ether Control has two modes, the Manual Mode and the Automatic Mode. If the other problems are suspected, perform the appropriate procedure in order to start the engine. Manual Mode : Problems with the Wiring Harness In the manual mode, as the ether switch is depressed there is a predetermined amount of ether that is injected.

The manual mode is disabled, if the engine speed is more than 200 rpm above the low idle, if the ambient air temperature is above 0 C (32 F), or if the coolant temperature is above 0 C 32 F. If the engine is equipped with the ether injection system, perform the following procedure for the manual mode: 1. Crank the engine. 2. Depress the ether switch. 3. Hold the ether switch for three seconds. 4. Release the ether switch. Automatic Mode : g00772964 Illustration 27 (1) ECM Connector J2/P2 (2) ECM Connector J1/P1