43 Operation Section Engine Starting Locate the ECM. Two harness connectors are attached to the ECM. One connector is ECM J2/P2 (1) and the other connector is ECM J1/P1. Check the connectors in order to ensure that the connectors are secure. Lightly pull each of the wires in the chassis harness. NOTICE Using a battery source with the same voltage as the electric starting motor. Use ONLY equal voltage for jump starting. The use of higher voltage will damage the electrical system. 1. Pull each wire with approximately 4.5 kg (10 lb) of force. The wire should remain in the connector. Do not reverse the battery cables. The alternator can be damaged. Attach ground cable last and remove first. 2.
If a wire is loose, push the wire back into the connector. Pull the wire again in order to ensure that the wire is secure. When using an external electrical source to start the engine, turn the engine control switch to the “OFF” po- sition. Turn all electrical accessories OFF before at- taching the jump start cables. 3. Start the engine. If the engine does not start, consult the nearest Caterpillar dealer for assistance. Ensure that the main power switch is in the OFF posi- tion before attaching the jump start cables to the en- gine being started. i01037941 Starting with Jump Start Cables 1. Turn the start switch on the stalled engine to the OFF position. Turn off all accessories. SMCS Code:
1000; 1401; 1402; 1900 2. Connect one positive end of the jump start cable to the positive cable terminal of the discharged battery. Connect the other positive end of the jump start cable to the positive cable terminal of the electrical source. Improper jump start cable connections can cause an explosion resulting in personal injury. 3. Connect one negative end of the jump start cable to the negative cable terminal of the electrical source. Connect the other negative end of the jump start cable to the engine block or to the chassis ground. This procedure helps to prevent potential sparks from igniting combustible gases that are produced by some batteries. Prevent sparks near the batteries.
Sparks could cause vapors to explode. Do not allow jump start cable ends to contact each other or the engine. If the installation is not equipped with a backup battery system, it may be necessary to start the engine from an external electrical source. 4. Charge the batteries. The engine will not continue to run after starting if the batteries have not been charged. First, determine the reason that it is necessary to start with power from an external source. Refer to Special Instruction, SEHS7768, “Use of the 6V-2150 Starting/Charging Analyzer”. 5. Start the engine. Many batteries which are considered unusable are still rechargeable.
After jump starting, the alternator may not be able to fully recharge batteries that are severely discharged. The batteries must be charged to the proper voltage with a battery charger. For information on testing and charging, refer to the Special Instruction, SEHS7633, “Battery Test Procedure”. 6. Immediately after the stalled engine is started, disconnect the jump start cables in reverse order. Refer to the Electrical Schematic for your engine. Consult your Caterpillar dealer for more information.