Caterpillar — Cooling System Specifications

60 Maintenance Section Cooling System Specifications Table 14 Formation of gel compounds Reduction of heat transfer Leakage of the water pump seal Plugging of radiators, coolers, and small passages Glycol Glycol in the coolant helps to provide protection against the following conditions: Boiling For a water analysis, consult one of the following sources: Freezing Caterpillar dealer For optimum performance, Caterpillar recommends a 1:1 mixture of a water/glycol solution. Local water utility company Note: Use a mixture that will provide protection against the lowest ambient temperature. Agricultural agent Note: 100 percent pure glycol will freeze at a temperature of 23 C ( 9 F).

Independent laboratory Additives Most conventional heavy-duty coolant/antifreezes use ethylene glycol. Propylene glycol may also be used. In a 1:1 mixture with water, ethylene and propylene glycol provide similar protection against freezing and boiling. See Tables 15 and 16. Additives help to protect the metal surfaces of the cooling system. A lack of coolant additives or insufficient amounts of additives enable the following conditions to occur:

Table 15 Corrosion Formation of mineral deposits Rust Scale Pitting and erosion from cavitation of the cylinder liner NOTICE Do not use propylene glycol in concentrations that ex- ceed 50 percent glycol because of propylene glycol’s reduced heat transfer capability. Use ethylene glycol in conditions that require additional protection against boiling or freezing. Foaming of the coolant Many additives are depleted during engine operation. These additives must be replaced periodically. This can be done by adding Supplemental Coolant Additives (SCA) to Diesel Engine Antifreeze/Coolant (DEAC) or by adding ELC Extender to Extended Life Coolant (ELC).

Additives must be added at the proper concentration. Overconcentration of additives can cause the inhibitors to drop out-of-solution. The deposits can enable the following problems to occur: Caterpillar Minimum Acceptable Water Requirements Property Maximum Limit ASTM Test Chloride (Cl) 40 mg/L (2.4 grains/US gal) “D512”, “D4327” Sulfate (SO) 4 100 mg/L (5.9 grains/US gal) “D516” Total Hardness 170 mg/L (10 grains/US gal) “D1126” Total Solids 340 mg/L (20 grain/US gal) “D1888” Acidity pH of 5.5 to 9.0 “D1293” Ethylene Glycol Concentration Freeze Protection Boil Protection 50 Percent   −36 C (−33 F)   106 C (223 F) 60 Percent   −51 C (−60 F)   111 C (232 F)