Caterpillar — Cooling System Specifications

61 Maintenance Section Cooling System Specifications Table 16 NOTICE All Caterpillar diesel engines equipped with air-to-air aftercooling (ATAAC) require a minimum of 30 percent glycol to prevent water pump cavitation. Table 17 To check the concentration of glycol, use the 1U-7298 Coolant/Battery Tester (Degree Celsius) or use the 1U-7297 Coolant/Battery Tester (Degree Fahrenheit). The testers give readings that are immediate and accurate. The testers can be used with ethylene or propylene glycol. i01096597 Coolant Recommendations SMCS Code: 1350; 1395 The following two coolants are used in Caterpillar diesel engines:

Preferred Caterpillar Extended Life Coolant (ELC) or a commercial extended life coolant that meets the Caterpillar EC-1 specification Acceptable A Caterpillar Diesel Engine Antifreeze/Coolant (DEAC) or a commercial heavy-duty coolant/antifreeze that meets “ASTM D4985” or “ASTM D5345” specifications i01200209 S·O·S Coolant Analysis SMCS Code: 1352; 1395; 7542 NOTICE Do not use a commercial coolant/antifreeze that only meets the ASTM D3306 or D4656 specification. This type of coolant/antifreeze is made for light duty auto- motive applications. Testing the engine coolant is important to ensure that the engine is protected from internal cavitation and from corrosion.

The analysis also tests the ability of the coolant to protect the engine from boiling and from freezing. The S·O·S Coolant Analysis can be done at your Caterpillar dealer. Caterpillar S·O·S Coolant Analysis is the best way to monitor the condition of your coolant and your cooling system. S·O·S Coolant Analysis is a program that is based on periodic samples. Caterpillar recommends a 1:1 mixture of water and glycol. This mixture of water and glycol will provide optimum heavy-duty performance as a coolant/antifreeze. Note: Caterpillar DEAC DOES NOT require a treatment with an SCA at the initial fill.

Commercial heavy-duty coolant/antifreeze that meets “ASTM D4985” or “ASTM D5345” specifications MAY require a treatment with an SCA at the initial fill. Read the label or the instructions that are provided by the OEM of the product. NOTICE Do not use the same vacuum sampling pump for ex- tracting oil samples that is used for extracting coolant samples. A small residue of either type sample may remain in the pump and may cause a false positive analysis for the sample being taken. In stationary engine applications and marine engine applications that do not require anti-boil protection or freeze protection, a mixture of SCA and water is acceptable.

Caterpillar recommends a six percent to eight percent concentration of SCA in those cooling systems. Distilled water or deionized water is preferred. Water which has the recommended properties may be used. Always use a designated pump for oil sampling and a designated pump for coolant sampling. Failure to do so may cause a false analysis which could lead to customer and dealer concerns.

Propylene Glycol Concentration Freeze Protection Boil Protection 50 Percent   −29 C (−20 F)   106 C (223 F) Coolant Service Life Coolant Type Service Life Caterpillar ELC 6000 Service Hours or Six Years Caterpillar DEAC 3000 Service Hours or Three Years Commercial Heavy-Duty Coolant/Antifreeze that meets “ASTM D5345” 3000 Service Hours or Two Years Commercial Heavy-Duty Coolant/Antifreeze that meets “ASTM D4985” 3000 Service Hours or One Year Caterpillar SCA and Water 3000 Service Hours or Two Years Commercial SCA and Water 3000 Service Hours or One Year