Caterpillar — Cooling System Specifications

62 Maintenance Section Cooling System Specifications New Systems, Refilled Systems, and Converted Systems Identification of buildup of the impurities that cause corrosion Perform a coolant analysis (Level 2) at 500 service hours for new systems, for refilled systems, or for converted systems that use ELC or use DEAC. This 500 hour check will also check for any residual cleaner that may have contaminated the system. Identification of buildup of the impurities that cause scaling Determination of possible electrolysis within the engines’ cooling system The results are reported, and appropriate recommendations are made.

Recommended Interval for S·O·S Coolant Sample For more information on S·O·S Coolant Analysis, consult your Caterpillar dealer. Perform a coolant analysis (Level 1) at every 500 service hour interval. Perform a coolant analysis (Level 2) annually. i01096605 Extended Life Coolant (ELC) Note: Check the standard coolant’s Supplemental Coolant Additive at every oil change. SMCS Code: 1350; 1395 S·O·S Coolant Analysis (Level 1) Caterpillar provides Extended Life Coolant (ELC) for use in the following applications: A coolant analysis (Level 1) is a test of the properties of the coolant. Heavy-duty spark ignited gas engines The following properties of the coolant are tested:

Heavy-duty diesel engines Glycol Concentration for freeze protection Automotive applications Ability to protect from erosion and corrosion The anti-corrosion package for Caterpillar ELC is different from the anti-corrosion package for other coolants. Caterpillar ELC is an ethylene glycol base coolant. However, Caterpillar ELC contains organic corrosion inhibitors and antifoam agents with low amounts of nitrite. Caterpillar ELC has been formulated with the correct amount of these additives in order to provide superior corrosion protection for all metals in engine cooling systems.

pH Conductivity Water hardness Visual analysis Odor analysis The results are reported, and appropriate recommendations are made. ELC extends the service life of the coolant to 6000 service hours or six years. ELC does not require a frequent addition of a Supplemental Coolant Additive (SCA). An Extender is the only additional maintenance that is needed at 3000 service hours or one half of the ELC service life. S·O·S Coolant Analysis (Level 2) Level 2 coolant analysis is a comprehensive chemical evaluation of the coolant. This analysis is also a check of the overall condition of the inside of the cooling system. ELC is available in a 1:1 premixed cooling solution with distilled water.

The Premixed ELC provides freeze protection to 36 C ( 33 F). The Premixed ELC is recommended for the initial fill of the cooling system. The Premixed ELC is also recommended for topping off the cooling system. The S·O·S Coolant Analysis has the following five features: ELC Concentrate is also available. ELC Concentrate can be used to lower the freezing point to 51 C ( 60 F) for arctic conditions. Full analysis of Level 1 Identification of the source of metal corrosion and of contaminants Containers of several sizes are available. Consult your Caterpillar dealer for the part numbers.