Caterpillar — Cooling System Specifications

67 Maintenance Section Cooling System Specifications Cooling Systems with Larger Capacities Table 21 Adding the SCA to Water at the Initial Fill Use the equation that is in Table 23 to determine the amount of Caterpillar SCA that is required at the initial fill. This equation is for a mixture of only SCA and water. Table 23 Equation For Adding The SCA To Water At The Initial Fill V Ч 0.07 = X V is the total volume of the cooling system. X is the amount of SCA that is required. Table 24 is an example for using the equation that is in Table 23. Table 24 Refer to Table 22 for part numbers and for quantities of SCA.

Table 22 Adding the SCA to Water for Maintenance For the recommended service interval, refer to the Operation and Maintenance Manual, “Maintenance Interval Schedule” for your engine. Use the 8T-5296 Coolant Conditioner Test Kit to test the concentration of SCA. Make the following modifications to Steps 3 and 5 of the 8T-5296 Coolant Conditioner Test Kit instructions: STEP 3 Add tap water to the vial up to the mark. Maintain the SCA in the same way as you would maintain a cooling system that uses heavy-duty coolant/antifreeze. Adjust the maintenance for the amount of SCA additions. See Table 21 for the amount of SCA that is required.

STEP 5 When the defined procedure is used, a concentration of six to eight percent will yield between 20 drops and 27 drops. If the number of drops is below 20 drops, the concentration of SCA is low. If the number of drops is above 27 drops, the concentration of SCA is high. Make the appropriate adjustments to the concentration of SCA. Test the concentration of SCA or submit a coolant sample to your Caterpillar dealer. See this publication, “S·O·S Coolant Analysis” topic (Maintenance Section).

Caterpillar SCA Requirements for SCA and Water Cooling Systems Cooling System Capacity Caterpillar SCA at Initial Fill Caterpillar SCA at 250 Hours 22 to 30 L (6 to 8 US gal) 1.75 L (64 fl oz) 0.44 L (15 fl oz) 31 to 38 L (9 to 10 US gal) 2.30 L (80 fl oz) 0.57 L (20 fl oz) 39 to 49 L (11 to 13 US gal) 3.00 L (100 fl oz) 0.75 L (25 fl oz) 50 to 64 L (14 to 17 US gal) 3.90 L (128 fl oz) 0.95 L (32 fl oz) 65 to 83 L (18 to 22 US gal) 5.00 L (168 fl oz) 1.25 L (42 fl oz) 84 to 110 L (23 to 29 US gal) 6.60 L (224 fl oz) 1.65 L (56 fl oz) 111 to 145 L (30 to 38 US gal) 8.75 L (296 fl oz) 2.19 L (74 fl oz) 146 to 190 L (39 to 50 US gal) 11.50 L (392 fl oz) 2.88 L (98 fl oz) 191 to 250 L (51 to 66 US gal) 15.00 L (512 fl oz) 3.75 L (128 fl oz) Example Of The Equation For Adding The SCA To Water At The Initial Fill Total Volume of the Cooling System (V) Multiplication Factor Amount of SCA that is Required (X) 946 L (250 US gal) × 0.07 66 L (18 US gal) Caterpillar Liquid SCA Part Number Quantity 6V-3542 0.24 L (8 oz) 111-2372 0.36 L (12 oz) 8T-1589 0.47 L (16 oz) 3P-2044 0.94 L (32 oz) 8C-3680 19 L (5 US gal) 5P-2907 208 L (55 US gal)