68 Maintenance Section Cooling System Specifications Additions of SCA are based on the results of the test or based on the results of the coolant analysis. The size of the cooling system determines the amount of SCA that is required. Check the coolant/antifreeze (glycol concentration) in order to ensure adequate protection against boiling or freezing. Caterpillar recommends the use of a refractometer for checking the glycol concentration. Use the 1U-7298 Coolant/Battery Tester (Degree Celsius) or use the 1U-7297 Coolant/Battery Tester (Degree Fahrenheit). The testers give readings that are immediate and accurate. The testers can be used with ethylene or with propylene glycol.

Use the equation that is in Table 23 to determine the amount of Caterpillar SCA that is required for maintenance, if necessary: Table 25 SCA To Water Addition Equation For Maintenance V Ч 0.023 = X Caterpillar engine cooling systems should be tested at 250 hour intervals for the concentration of Supplemental Coolant Additive (SCA). SCA test kits are available from your Caterpillar dealer. Test the concentration of SCA or submit a coolant sample to your Caterpillar dealer at 250 hour intervals. Refer to S·O·S Coolant Analysis for more information on this topic. V is the total volume of the cooling system. X is the amount of SCA that is required.

Table 26 is an example for using the equation that is in Table 23. Table 26 Additions of SCA are based on the results of the test or based on the results of the coolant analysis. An SCA that is liquid or a maintenance element for an SCA (if equipped) may be needed at 250 hour intervals. Table 27 lists the amount of Caterpillar SCA that is needed at the initial fill in order to treat coolant/antifreeze. These amounts of SCA are for systems that use heavy-duty coolant/antifreeze. Note: Specific engine applications may require maintenance practices to be periodically evaluated in order to properly maintain the engine’s cooling system.

Table 27 also lists additions of SCA for liquid and for maintenance elements at 250 hours. The additions are required for Caterpillar DEAC and for commercial coolant/antifreezes. Table 22 lists part numbers and quantities of SCA that is available from your Caterpillar dealer. i01570193 Conventional Coolant/ Antifreeze Cooling System Maintenance SMCS Code: 1350; 1352; 1395 NOTICE Never operate an engine without water temperature regulators in the cooling system. Water temperature regulators help to maintain the engine coolant at the proper operating temperature. Cooling system prob- lems can develop without water temperature regula- tors.

SCA To Water Addition Equation Example For Maintenance Total Volume of the Cooling System (V) Multiplication Factor Amount of SCA that is Required (X) 946 L (250 US gal) × 0.023 22 L (6 US gal)