74 Maintenance Section Aftercooler Core - Clean/Test i01546702 Aftercooler Core - Clean/Test 7. Inspect the core in order to ensure cleanliness. Pressure test the core. Many shops that service radiators are equipped to perform pressure tests. If necessary, repair the core. SMCS Code: 1064-070; 1064-081 8. Install the core. Refer to the Service Manual for the procedure. 1. Remove the core. Refer to the Service Manual for the procedure. 2. Turn the aftercooler core upside-down in order to remove debris. For more information on cleaning the core, consult your Caterpillar dealer. NOTICE Do not use a high concentration of caustic cleaner to clean the core.
A high concentration of caustic cleaner can attack the internal metals of the core and cause leakage. Only use the recommended concentration of cleaner. i01468985 Aftercooler Core - Inspect SMCS Code: 1064-040 Note: Adjust the frequency of cleaning according to the effects of the operating environment. 3. Back flush the core with cleaner. Caterpillar recommends the use of Hydrosolv liquid cleaner. Table 35 lists Hydrosolv liquid cleaners that are available from your Caterpillar dealer. Inspect the aftercooler for these items: damaged fins, corrosion, dirt, grease, insects, leaves, oil, and other debris. Clean the aftercooler, if necessary.
For air-to-air aftercoolers, use the same methods that are used for cleaning radiators. Table 35 Personal injury can result from air pressure. Personal injury can result without following prop- er procedure. When using pressure air, wear a pro- tective face shield and protective clothing. (1) Use a two to five percent concentration of the cleaner at temperatures up to 93 C (200 F). Refer to Application Guide, NEHS0526 or consult your Caterpillar dealer for more information. Maximum air pressure at the nozzle must be less than 205 kPa (30 psi) for cleaning purposes. 4. Steam clean the core in order to remove any residue. Flush the fins of the aftercooler core. Remove any other trapped debris.
Pressurized air is the preferred method for removing loose debris. Direct the air in the opposite direction of the fan’s air flow. Hold the nozzle approximately 6 mm (.25 inch) away from the fins. Slowly move the air nozzle in a direction that is parallel with the tubes. This will remove debris that is between the tubes. 5. Wash the core with hot, soapy water. Rinse the core thoroughly with clean water. Personal injury can result from air pressure. Pressurized water may also be used for cleaning. The maximum water pressure for cleaning purposes must be less than 275 kPa (40 psi). Use pressurized water in order to soften mud. Clean the core from both sides.
Personal injury can result without following prop- er procedure. When using pressure air, wear a pro- tective face shield and protective clothing. Maximum air pressure at the nozzle must be less than 205 kPa (30 psi) for cleaning purposes. Use a degreaser and steam for removal of oil and grease. Clean both sides of the core. Wash the core with detergent and hot water. Thoroughly rinse the core with clean water. 6. Dry the core with compressed air. Direct the air in the reverse direction of the normal flow. Hydrosolv Liquid Cleaners(1) Part Number Description Size 1U-5490 Hydrosolv 4165 19 L (5 US gallon) 174-6854 Hydrosolv 100 19 L (5 US gallon)