Caterpillar — Maintenance Interval Schedule

81 Maintenance Section Cooling System Coolant (DEAC) - Change Note: Inspect the water pump and the water temperature regulator after the cooling system has been drained. This is a good opportunity to replace the water pump, the water temperature regulator and the hoses, if necessary. 3. Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 15 L (4 US gal) of the cooling system capacity. Install the cooling system filler cap. Drain 4. Start and run the engine at low idle for a minimum of 30 minutes. The coolant temperature should be at least 82 C (180 F).

NOTICE Improper or incomplete rinsing of the cooling system can result in damage to copper and other metal com- ponents. Pressurized System: Hot coolant can cause seri- ous burns. To open the cooling system filler cap, stop the engine and wait until the cooling system components are cool. Loosen the cooling system pressure cap slowly in order to relieve the pres- sure. To avoid damage to the cooling system, make sure to completely flush the cooling system with clear wa- ter. Continue to flush the system until all signs of the cleaning agent are gone. 1. Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure.

Remove the cooling system filler cap. 5. Stop the engine and allow the engine to cool. Loosen the cooling system filler cap slowly in order to relieve any pressure. Remove the cooling system filler cap. Open the drain valve (if equipped) or remove the cooling system drain plugs. Allow the water to drain. Flush the cooling system with clean water. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Operation and Maintenance Manual, “Torque Specifications” topic (Maintenance Section) for more information on the proper torques. 2. Open the cooling system drain valve (if equipped).

If the cooling system is not equipped with a drain valve, remove one of the drain plugs. Allow the coolant to drain. NOTICE Dispose of used engine coolant properly or recycle. Various methods have been proposed to reclaim used coolant for reuse in engine cooling systems. The full distillation procedure is the only method acceptable by Caterpillar to reclaim the used coolant. Cooling Systems with Heavy Deposits or Plugging For information regarding the disposal and the recycling of used coolant, consult your Caterpillar dealer or consult Caterpillar Service Technology Group: Note:

For the following procedure to be effective, there must be some active flow through the cooling system components. Outside Illinois: 1-800-542-TOOL Inside Illinois: 1-800-541-TOOL Canada: 1-800-523-TOOL 1. Flush the cooling system with clean water in order to remove any debris. 2. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs. Refer to the Operation and Maintenance Manual, “Torque Specifications” topic (Maintenance Section) for more information on the proper torques. Flush 1. Flush the cooling system with clean water in order to remove any debris. 2. Close the drain valve (if equipped). Clean the drain plugs. Install the drain plugs.

Refer to the Operation and Maintenance Manual, “Torque Specifications” topic (Maintenance Section) for more information on the proper torques. NOTICE Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks. 3. Fill the cooling system with a mixture of clean water and Caterpillar Fast Acting Cooling System Cleaner. Add 0.5 L (1 pint) of cleaner per 3.8 to 7.6 L (1 to 2 US gal) of the cooling system capacity. Install the cooling system filler cap. NOTICE Fill the cooling system no faster than 19 L (5 US gal) per minute to avoid air locks.