87 Maintenance Section Cylinder Head Grounding Stud - Inspect/Clean/Tighten Visconic Damper i00174798 Driven Equipment - Check The visconic damper has a weight that is located inside a fluid filled case. The weight moves in the case in order to limit torsional vibration. Inspect the damper for evidence of dents, cracks or leaks of the fluid. SMCS Code: 3279-535 Refer to the OEM specifications for more information on the following maintenance recommendations for the driven equipment: Replace the damper if the damper is dented, cracked or leaking. Refer to the Service Manual or consult your Caterpillar dealer for damper replacement.
Inspection Adjustment i01473487 Cylinder Head Grounding Stud - Inspect/Clean/Tighten Lubrication Other maintenance recommendations Perform any maintenance for the driven equipment which is recommended by the OEM. SMCS Code: 7423-040; 7423-070; 7423-079 i01646701 Engine - Clean SMCS Code: 1000-070 Personal injury or death can result from high volt- age. Moisture can create paths of electrical conductiv- ity. Make sure that the electrical system is OFF. Lock out the starting controls and tag the controls “DO NOT OPERATE”. g00768411 Illustration 37 NOTICE Accumulated grease and oil on an engine is a fire haz- ard. Keep the engine clean.
Remove debris and fluid spills whenever a significant quantity accumulates on the engine. Typical example Inspect the OEM harness for good connections and condition. Periodic cleaning of the engine is recommended. Steam cleaning the engine will remove accumulated oil and grease. A clean engine provides the following benefits: The electrical grounding stud must have a wire ground to the battery. Tighten the electrical grounding stud at every oil change. Ground wires and straps should be combined at engine grounds. All grounds should be tight and free of corrosion. Easy detection of fluid leaks If the connections are corroded, clean the connections with a solution of baking soda and water.
Maximum heat transfer characteristics Ease of maintenance Keep the electrical grounding stud and the strap clean and coated with MPGM grease or petroleum jelly.