98 Maintenance Section Ether Starting Aid Cylinder - Replace i00805059 Ether Starting Aid Cylinder - Replace (If Equipped) Lubricate the grease fitting that is on the fan drive bearing with Bearing Lubricant or the equivalent. Inspect the fan drive pulley assembly for wear or for damage. If the shaft is loose, an inspection of the internal components should be performed. Refer to the Service Manual for additional information. SMCS Code: 1456-510-CD i01091827 Fuel System - Prime SMCS Code: 1258-548 Fuel leaked or spilled onto hot surfaces or elec- trical components can cause a fire.
To help pre- vent possible injury, turn the start switch off when changing fuel filters or water separator elements. Clean up fuel spills immediately. g00104888 Illustration 50 NOTICE Do not allow dirt to enter the fuel system. Thoroughly clean the area around a fuel system component that will be disconnected. Fit a suitable cover over any dis- connected fuel system components. Typical example 1. Loosen the ether cylinder clamp. Unscrew and remove the empty ether cylinder. 2. Remove the used gasket. Install the new gasket that is provided with each new ether cylinder. Prime the fuel system in order to fill the fuel filter. Prime the fuel system in order to purge trapped air.
The fuel system should be primed under the following conditions: 3. Install the new ether cylinder. Hand tighten the ether cylinder. Tighten the ether cylinder clamp securely. Running out of fuel i01423301 Fan Drive Bearing - Lubricate Storage Replacement of the fuel filter SMCS Code: 1359-086-BD Engines that are Equipped with a Fuel Priming Pump NOTICE Do not loosen the fuel lines at the fuel manifold. The fittings may be damaged and/or a loss of priming pres- sure may occur when the fuel lines are loosened. 1. Open the fuel priming pump and operate the fuel priming pump until a strong pressure is felt. This procedure will require considerable strokes. Lock the fuel priming pump.
g00746166 Illustration 51 Typical location of the grease fitting that is for the fan drive bearing NOTICE Do not crank the engine continuously for more than 30 seconds. Allow the starting motor to cool for two minutes before cranking the engine again. The pulley is shown with the belt guards removed