97 Maintenance Section Engine Storage Procedure - Check i01430860 Engine Storage Procedure - Check Ensure that the engine can not be started while this maintenance is being performed. To help pre- vent possible injury, do not use the starting motor to turn the flywheel. SMCS Code: 1000-535 Caterpillar requires all engines that are stored for more than 3 months to follow storage procedures and start-up procedures. These procedures provide maximum protection to internal engine components. Refer to Special Instruction, SEHS9031, “Storage Procedure For Caterpillar Products” for information on these procedures. Hot engine components can cause burns.
Allow additional time for the engine to cool before mea- suring/adjusting valve lash clearance. Ensure that the engine is stopped before measuring the valve lash. To obtain an accurate measurement, allow the valves to cool before this maintenance is performed. An extension of the oil change interval to 12 months is permitted if you follow the required procedures for storage and start-up. This extension is permitted if the following intervals in the Operation and Maintenance Manual, “Maintenance Interval Schedule” have not been reached: Refer to the Service Manual for more information. i01597115 Engine Valve Rotators - Inspect Operating hours SMCS Code:
1109-040 Fuel consumption i00869628 Engine Valve Lash - Inspect/Adjust When inspecting the valve rotators, protective glasses or face shield and protective clothing must be worn, to help prevent being burned by hot oil or spray. SMCS Code: 1102-025 The initial valve lash adjustment on new engines, rebuilt engines, or remanufactured engines is recommended at the first scheduled oil change. The adjustment is necessary due to the initial wear of the valve train components and to the seating of the valve train components. Engine valve rotators rotate the valves when the engine runs. This helps to prevent deposits from building up on the valves and the valve seats.
Perform the following steps after the engine valve lash is set, but before the valve covers are installed: This maintenance is recommended by Caterpillar as part of a lubrication and preventive maintenance schedule in order to help provide maximum engine life. 1. Start the engine according to Operation and Maintenance Manual, “Engine Starting” (Operation Section) for the procedure. 2. Operate the engine at low idle. NOTICE Only qualified service personnel should perform this maintenance. Refer to the Service Manual or your Caterpillar dealer for the complete valve lash adjust- ment procedure. 3. Observe the top surface of each valve rotator.
The valve rotators should turn slightly when the valves close. NOTICE A valve rotator which does not operate properly will accelerate valve face wear and valve seat wear and shorten valve life. If a damaged rotator is not replaced, valve face guttering could result and cause pieces of the valve to fall into the cylinder. This can cause piston and cylinder head damage. Operation of Caterpillar engines with improper valve adjustments can reduce engine efficiency. This re- duced efficiency could result in excessive fuel usage and/or shortened engine component life. If a valve fails to rotate, consult your Caterpillar dealer.