Komatsu — CHECK, CLEAN ADDITIONAL FUEL STRAINER

. MAINTENANCE SERVICE PROCEDURE 4 - 49 CHECK, CLEAN ADDITIONAL FUEL STRAINE (If equipped) 1. Open cover (1) 2. Clos e fuel supply valve (2), then remove strainer cap (3). The s trainer forms one unit with the strainer cap. 3. Remove any dir t stuck to the strainer , then wash in clean diesel fuel o r flushing oil. If the strainer is d amaged, replace it. 4. After an cleaning, install trainer, then ighten cap ( 3). 5. After installing, open fue l supply valve (2)