Aegis LH630-775 — Section 8 - Electrical System

Section 8 Electrical System and Components Reported ignition problems are most often due to poor connections. Before beginning the test procedure, check all external wiring. Be certain all ignition-related wires are connected, including the spark plug leads. Be certain all terminal connections fit snugly. Make sure the ignition switch is in the run position. b. If the tester shows spark, but the engine misses or won’t run on that cylinder, try a new spark plug. c. If neither side is firing, recheck position of ignition switch and check for shorted kill lead. NOTE: The CD ignition systems are sensitive to excessive load on the kill lead.

If a customer complains of hard starting, low power, or misfire under load, it may be due to excessive draw on the kill circuit. Perform the preliminary test which follows. Battery Charging System General These engines are equipped with either a 15, 20 or 25 amp regulated charging system. See Figure 8-6 for the 15/20/25 amp system diagram. Preliminary Test To be certain the reported problem is in the engine ignition system, it should be isolated from the unit. NOTE: Observe the following guidelines to avoid damage to the electrical system and components: 1. Locate the plug connectors where the wiring harnesses from the engine and unit are joined.

Separate the connectors and remove the white ‘‘kill’’ lead from the engine connector. Rejoin the connectors and position or insulate the kill lead terminal so it cannot touch ground. Try to start* the engine to verify whether the reported problem is still present. Make sure the battery polarity is correct. A negative (-) ground system is used. Disconnect the plug from the rectifier-regulator and the battery cables before doing electric welding on the equipment powered by the engine. a. If the problem is gone, the electrical system on the unit is suspect. Check the key switch, wires, connections, safety interlocks, etc.

Prevent the stator (AC) leads from touching or shorting while the engine is running. This could damage the stator. b. If the problem persists, follow the test procedure on the next page. Leave the kill lead isolated until all testing is completed. Wiring Color Codes B L R Y W P O L/R Black Blue Red Yellow White Purple Orange Blue/Red *NOTE: If the engine starts or runs during any of the testing, you may need to ground the kill lead to shut it down. As you have interrupted the kill circuit, it may not stop with the switch. 2. Test for spark on both cylinders with Kohler ignition tester (see Section 2). Disconnect one spark plug lead and connect it to the post terminal of the tester.

Connect the clip to a good ground, not to the spark plug. Crank the engine and observe the tester spark gap. Repeat the procedure on the other cylinder. Remember to reconnect the first spark plug lead. a. If one side is not firing, check all wiring, connections, and terminations on that side. If wiring is okay, replace ignition module and retest for spark. 8.6