Section 8 Electrical System and Components Stator The stator is mounted on the crankcase behind the flywheel. If the stator needs to be replaced, follow the procedures in Section 9 - “Disassembly.” Rectifier-Regulator The rectifier-regulator is mounted on the bracket below the overflow reservoir. See Figure 8-8. To replace it; disconnect the connector plug and remove the two screws. Take off the rectifier-regulator. NOTE: When installing the rectifier-regulator, make sure the cooling fins are "in", towards the fan. Figure 8-9. 3. Plug the tester into the proper AC outlet/power for tester being used. Turn on the power switch. See Figure 8-10.

The ‘‘POWER’’ light should be illuminated and one of the four status lights may be on as well. This does not represent the condition of the part. Figure 8-8. Rectifier-Regulator. Testing of the rectifier-regulator may be performed as follows, using the appropriate Rectifier-Regulator Tester (see Section 2). To Test – NOTE: Disconnect all electrical connections attached to the rectifier-regulator. Testing may be performed with the rectifier-regulator mounted or loose. The figures show the part removed from the engine for clarity. Repeat the applicable test procedure two or three times to determine the condition of the part. Figure 8-10. 4.

Press the ‘‘TEST’’ button until a “click” is heard and then release. See Figure 8-11. Momentarily one of the four lights will illuminate, indicating the condition of the part. 15 Amp Rectifier-Regulators 1. Connect the tester ground lead (with spring clamp) to the body of the rectifier-regulator being tested. 2. Connect the tester red lead to the B+ terminal of the rectifier-regulator and the two black tester leads to the two AC terminals. See Figure 8-9. 8.8