Section 8 Electrical System and Components 3. Connect the red lead and one of the black leads to the pair of terminals on the open end of the tandem adapter lead (connections are not location specific). 4. Connect the remaining black lead from the tester to one of the outer AC terminals on the rectifier- regulator. See Figure 8-13. Figure 8-11. a. If the “OK” (green) light comes on and stays steady, the part is good and may be used. b. If any other light is displayed,* the rectifier- regulator is faulty and should not be used. *NOTE: A flashing “LOW” light can also occur as a result of an inadequate ground lead connection. Make certain connection location is clean and clamp is secure.
Figure 8-13. 5. Plug the tester into the proper AC outlet/power for tester being used. Turn on the power switch. The ‘‘POWER’’ light should be illuminated and one of the four status lights may be on as well. See Figure 8-10. This does not represent the condition of the part. 20/25 Amp Rectifier-Regulators 1. Connect the single lead adapter in between the B+ (center) terminal of rectifier-regulator being tested and the squared single end of the tandem adapter lead. See Figure 8-12. 8 6. Press the ‘‘TEST’’ button until a ‘‘click’’ is heard and then release. See Figure 8-11. Momentarily one of the four lights will illuminate indicating the partial condition of the part. a.
If the ‘‘OK’’ (green) light comes on, disconnect the tester black lead attached to one AC terminal and reconnect it to the other AC terminal. Repeat the test. If the ‘‘OK’’ (green) light comes on again, the part is good and may be used. b. If any other light is displayed* in either of the tests, the rectifier-regulator is faulty and should not be used. Figure 8-12. 2. Connect the tester ground lead (with spring clamp) to the body of the rectifier-regulator. *NOTE: A flashing ‘‘LOW’’ light can also occur as a result of an inadequate ground lead connection. Make certain the connection location is clean and the clamp is secure. 8.9