Komatsu — FUSE

. LOADING SHOVEL EXPLANATION OF COMPONENTS FUSE Replace the fuse with another of the same capacity. Fuse Capacities and Circuit Name 7 - 5 NOTIC E Before replacing a fuse, be sure to turn off the s tarting switch. The f uses protec t the electrical equipment and wiring from burning out. If the fuse i fuse becomes s loose in the corroded, o fuse holder, r white powder can be seen, or the replace the fuse. No.

Fuse Capacity Circuit Name (1) 10A Redundancy, Swing holding brake solenoid valve (2) 10A Solenoid valve (3) 10A PPC lock solenoid, Starting motor cut-out relay (4) 20A Window washer, Cigarette lighter (5) 10A Horn,flashlight (OPT), Bottom dump solenoid valve (Close) (6) 10A Ribbon heater relay (7) 10A Revolving warning lamp (OPT) (8) 10A Spare fuse (9) 10A Radio, Bottom dump solenoid valve (Open) (10) 20A Monitors, Buzzer (11) 25A Air conditioner unit (12) 20A Spare fuse (13) 20A Spare fuse (14) 10A OPT power supply (1) (15) 10A OPT power supply (2), 12V power supply (OPT) (16) 10A Radio backup, Room lamp (17) 10A Step light (OPT) (18) 10A Spare fuse (19) 10A Spare fuse (20) 5A ACC (ENGINE CON)