. MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE machine. REMARK Steam or water can be used instead of compressed air. 4 - 31 4. Check that the pilot lamp ins ide the switch and the cooling fan reverse rotation pilot lamp o n the machine monitor are lighted up. At the same time, "COOLING FAN REVERSE" is displayed on the character d isplay, and the fan is set to reverse rotation. Turn the key in the starting 5. start the engine. The cooling fan will rotate in 6. Run the engine at high idle. Select the time for running t he engine at high idle as follows according to the conditio n of clogg Normal clogging: 1 to 2 min Excessive clogging: 2 to 3 7.
After completing the cleanin g, run the engine at low idle for approx. 10 8. Turn the starting switch to t he OFF position and stop the engine. 9. When the fan rotation stops, loosen wing bolts (2), use hook (3) to slide cleaning covers (4), and open the left and right covers. 10. 11. After blowing out the dirt, in (4). Run the engine at low idle. 12. 13. Turn the key in the starting switch to the OFF position and stop the 14. Turn starting switch key to t 15. Set cooling fan reverse rotat ion switch (1) to position (b) (OFF) to cancel the reverse rotatio 16. Check the rubber hose. Rep lace with a new one if the hose is found to have cracks or to b Also, check hose clamps fo