Daimler Trucks North America LLC Western Star — Western Star

Rear Axle 35 3. Place a drain pan under the rear axle drain plug; see Fig. 3 . Drain the oil at normal operating tem- perature, 150°F to 200°F (65°C to 93°C). At this temperature, the oil will run more freely and en- sure that the axle is flushed. NOTE: Some tandem-drive axles are equipped with a cylindrical magnetic strainer, located below the lube pump on the front of the power divider cover. All rear axles are fitted with mag- netic drain and fill plugs. 4.3 Install and tighten the magnetic strainer 40 to 60 lbf·ft (54 to 81 N·m). 5. Clean the fill and drain plugs as follows. Change them if necessary.

5.1 For magnetic plugs, use a piece of key stock or any other convenient steel slug to short the two magnetic poles and divert the magnetic field. 5.2 Clean away the collected material depos- ited on each pole. Magnets will rapidly lose their effectiveness as collected mate- rial bridges the gap between the two poles. 4. At each axle oil change, remove and clean the magnetic strainer, if equipped, as follows. 4.1 Remove the magnetic strainer from the power divider cover. See Fig. 8 . 5.3 Inspect the drain plug for large quantities of metal particles. 5.4 After cleaning, install the drain plug(s) and tighten to 40 to 60 lbf·ft (54 to 81 N·m). IMPORTANT:

The use of friction modifiers is not approved in Dana drive axles. 6. Fill the axle with the recommended lubricant as follows. See Table 6 for recommended lubri- cants, and Table 7 for drive axle lubricant ca- pacities. 2 6.1 With the vehicle on a level surface, fill the axle through the oil fill hole. Lubricant should be level with the bottom of the oil fill hole. 1 6.2 Check the fluid level; see Fig. 4 . 05/27/93 6.3 Install and tighten the fill plug 50 lbf·ft (68 N·m). f350017a 1. Magnetic Strainer 2. Power Divider Fig.

8, Dana Spicer Tandem-Drive Axle Magnetic Strainer WARNING Always wear eye protection when using com- pressed air to clean parts, as flying debris could cause permanent damage to unprotected eyes. Do not point the air stream in the direction of other persons. 4.2 Wash the strainer in solvent, and blow it dry with compressed air to remove oil and metal particles. Western Star Maintenance Manual, September 2015 35/7