Brakes 42 Brake Chamber Stroke Specifications Chamber Max Applied Stroke: inch (mm) Manufacturer Type * Size 9 Less than 1-1/2 (38) 12 Standard Stroke 16 Less than 1-3/4 (44) 20 Meritor 24 Less than 1-7/8 (48) Long Stroke 24 Less than 2 (51) Standard Stroke 30 * Long stroke design is indicated by a tag, or embossing, on the brake chamber. Specifications are relative to a brake application with 80 to 90 psi (550 to 620 kPa) air pressure in the brake chambers. If type 36 chamber is used, slack length should be less than 6 inches. Table 1, Brake Chamber Stroke Specifications 42–08 Versajust Slack Adjuster Inspection and Lubrication any components are damaged, repair or replace them as necessary.
3. Measure the brake actuator pushrod stroke while making an 80 to 90 psi (552 to 621 kPa) brake application. Actuator pushrod strokes should not exceed the values shown in Table 2 and Table 3 . To achieve the correct pressure for this test, build the system pressure up to a 100 psi (690 kPa). Shut down the engine. Fan the brakes to attain a 90 to 95 psi (621 to 655 kPa) reading. Make and hold a full brake application while the strokes are checked. IMPORTANT: Perform the Brake Inspection maintenance operation before lubricating the slack adjusters. 1. Visually check for physical damage, such as bro- ken air lines and broken or missing parts. 2.
Using a quality multipurpose chassis lubricant, NLGI Grade 2, lubricate the slack adjuster through the grease fitting until clean lubricant flows from the grease relief opening in the boot. Actuator Stroke–Standard Stroke Brake Actuator Size Recommended Maximum Operating Stroke (Inches) 3. Perform the "In Service Inspection." In Service Inspection 30 2 24 1-3/4 1. Apply and release the brakes several times while observing the slack adjuster. The slack adjuster and brake actuator should move freely, without binding or interference, and should return to the full released position.
Observe the looseness that exists between the clevis and adapter bushing and the yoke and link pins and their mating parts (clevis, body, link). Replace these parts if loose- ness appears excessive. Make certain the brake actuator pushrod jam nut is tightened securely. 20 1-3/4 16 1-3/4 12 1-3/8 Table 2, Actuator Stroke–Standard Stroke Actuator Stroke–Long Stroke Brake Actuator Size Recommended Maximum Operating Stroke (Inches) 2. Inspect the slack adjuster for physical damage, paying attention to the link, boot, and clevis. If 30 Long Stroke 2-1/2 24 Long 2 Western Star Maintenance Manual, September 2015 42/10