MAINTENANCE PROCEDURE 4.9.1.b CLEAN INSIDE OF COOLING SYSTEM Immediately after the engine is stopped, the coolant is at a high temperature and the radiator is under high internal pressure. If the cap is removed to drain the coolant in this condition, there is a hazard of burns. Wait for the temperature to go down, then turn the cap slowly to release the pressure before re moving it. Cleaning is carried out with the engine running. When standing up or leaving the operator's seat, set the safety lock lever to the LOCK position. For details of starting the engine, see "3.3.1 BEFORE STARTING ENGINE" and "3.3.1.5 STARTING EN GINE" in the "3.3 MACHINE OPERATIONS AND CONTROLS" section.
The engine is operated when washing, so it is dangerous if the machine moves when you are standing behind it. Never stand behind the machine when the engine is running. Stop the machine on level ground when cleaning or changing the coolant. Clean the inside of the cooling system, change the coolant and replace the corrosion resistor according to the ta- ble below. Use a permanent type of antifreeze. If, for some reason, it is impossible to use permanent type antifreeze, use an antifreeze containing ethylene glycol. The proportion of the mixture differs according to the ambient temperature, but to obtain the corrosion resistance effect, a minimum of 30% by volume is necessary.
When deciding the ratio of antifreeze to water, check the lowest temperature in the past, and decide from the mix- ing rate table given below. It is actually better to estimate a temperature about 10°C (18°F) lower when deciding the mixing rate. Mixing rate of water and antifreeze 175 WARNING Kind of coolant Cleaning inside of cooling system and changing coolant Adding corrosion resistor agent KI Permanent type antifreeze (All season type) Every year (autumn) or every 2000 hours whichever comes first Every 1000 hours and when cleaning the inside of the cooling system and when changing coolant.
Non-permanent type antifreeze containing ethylene glycol (winter, one season type) Every 6 months (spring and autumn) (Drain antifreeze in spring, add antifreeze in autumn) When not using antifreeze Every 6 months or every 1000 hours whichever comes first Min. atomspheric temperature °C Above -10 -15 -20 -25 -30 Amount of antifreeze Liters 1.0 1.1 1.4 1.5 1.6 Amount of water Liters 2.3 2.2 1.9 1.8 1.7