MAINTENANCE PROCEDURE 4.9.1.o BLEEDING AIR FROM HYDRAULIC SYSTEM IMPORTANT If the pump is operated without filling the pump case with hydraulic oil, there is danger that the pump may be prematurely damaged. Be sure to bleed the air completely. 1. Bleeding air from piston pump. 2. Remove 3 M10 bolts (1), then remove triangular cover (2). 3. Remove the oil filler cap from the hydraulic oil tank. 4. Loosen air bleed plug (3) and check that oil oozes out from the bleeder plug (completion of air bleeding). PC30MR-2 5. After completion of the air bleeding operation, tighten the air bleed plug. 6. Tighten the oil filler cap of the hydraylic oil tank. 7. Install the cover. 8. Start the engine.
For details, see "3.3.1.5 STARTING EN GINE". Run the engine at low idling for 10 minutes, then do as follows. 9. Bleeding air from cylinders IMPORTANT If the engine is run at high speed immediately after star tup or a cylinder is pushed up to its stroke end, air taken inside the cylinder may cause damage to the piston packing. PC35MR-2 10. Run the engine at low idling, and extend and retract each cylinder 4 to 5 times, taking care so that a cylinder may not be brought up to its stroke end. (Stop the cylinder ap prox. 100 mm (3.9 in.) short of its stroke end). 11. Next, operate each cylinder 3 to 4 times to the end of its stroke. 12.
Finally, operate each cylinder 4 to 5 times to the end of its stroke to completely remove the air. 13. Bleeding air from attachment (when installed) IMPORTANT If the method of bleeding the air from the attachment itself is specified by the manufacturer, bleed the air according to the specified procedure. After completing the air bleeding operation, stop the engine, and leave the machine for 5 minutes before starting operations. This will remove the air bubbles in the oil inside the hydraulic cylinders. Check that there is no leakage of oil and wipe off any oil that has been spilled.
If a breaker or other attachment has been installed, run the engine at low idling and operate the attachment pedal repeatedly (approx. 10 times) until the air has been bled from the attachment circuit. 190