. MAINTENANCE SERVICE PROCEDURE MAINTENANCE SERVICE PROCEDURE start. 4 - 35 3. Open a ir bleeding val 4. Operat positio n. Lam p (4) wil l flash and th e electric p riming pu mp wi REMARK ctric priming pump switch has a built-in timer, and this actuates and stops the pump automatically. e lamp is flashing, the electric priming pump will stop, but this does not indicate any abnormality.
The ele ctric priming p ump switch h as a built-in timer, a nd this actuates and stops th While th e lamp is flash ing, the elec tric priming pump wi ll stop, but this does not indi If the sw itch is t urned t o the OFF po sition when the lamp is lighted up, the lamp will go out and the electric priming pump w ill stop. 5. When the specified t ime (approx. 7 minutes) has passed, lamp (4) automatically goes out and the electric priming pump stops. 6.
If the f uel has been d rained from t he fuel circuit, such as when the engine has run out of fuel and stopped, or maintenance has bee n carried ou t on the fuel hoses o r tubes , or the supply pump h as been replaced, turn the switch for the electric priming pum p to the ON position again a fter the electric primin g pump stops automatically (lamp g oes out).