OPERATING MACHINE Pilot Control Shut-Off Lever 1 The pilot control shut-off lever is a device to prevent the machine from being unexpectedly operated even if the control levers are accidentally moved, such as with a part of the body or when the operator is getting in or out of the operator’s station. Pilot control shut-off lever (1) is linked to console (2) latch mechanism so that console (2) is raised in the LOCK position to aid in entering and exiting the operator’s station and for maintenance. d WARNING: 2 To deactivate control lever and pedal functions, be sure to pull pilot control shut-off lever (1) and raise console (2) to the fully locked position.

To reactivate control lever (3) function, always hold and push pilot control shut-off lever (1) down. Never attempt to lower raised console (2) or control levers (3) to reactivate control lever (3) function without holding pilot control shut-off lever (1). Lock Position M1NC-05-004 Always stop the engine and pull pilot control shut-off lever (1) to the full LOCK position before exiting the operator’s station, even when exiting temporarily. 1 3 Be sure to move the pilot control shut-off lever to the LOCK position before exiting the machine after each shift. Before Leaving the Machine: 1. Park the machine on a firm, level surface. Lower the bucket and blade to the ground.

Return all control levers to neutral. Stop the engine. 2. To deactivate control lever (3) function, be sure to pull pilot control shut-off lever (1) and raise console (2) to the fully locked position. Unlock Position M1NC-01-013 5-8