hitachi — Hitachi ZX14-3/ZX16-3/ZX18-3/ZX27-3 Hydraulic Excavator Operator's Manual

MAINTENANCE E. Fuel System (See Page 7-44) Fuel tank capacity: ZX14-3, 16-3, 18-3: 22 L, ZX27-3: 47 L f NOTE: The fuel filter may become clogged earlier than normal due to contaminated fuel. In case the engine power is reduced, or black smoke increases, shorten the intervals of inspection/maintenance. F. Air Cleaner (See Page 7-49) f NOTE: Shorten the interval in a dusty work site. G. Cooling System (See Page 7-51) f NOTE: Shorten maintenance interval in dusty work site. For the first time only. f NOTE: When genuine Hitachi long life coolant (LLC) is used, replace it every two years (in autumn) or after 2000 operating hours, whichever comes first. IMPORTANT: Use soft water for the coolant.

Avoid using strong acid, alkaline water, hard water or natural water. Be sure to use genuine Hitachi long life coolant (LLC). In case genuine Hitachi long life coolant is not available, use other long life coolant conforming to one of the specifications below. • JIS K-2234 • SAE J814 • SAE J1034 • ASTM D3306 7-10 Parts Quantity Interval (hours) 8 50 100 250 500 1000 2000 1. Check Water Separator 1 2. Drain Fuel Tank Sump 1 As needed 3. Replace Fuel Filter 1 4. Check Fuel Hoses for leaks, cracks, etc. − for cracks, bend, etc. − Parts Quantity Interval (hours) 8 50 100 250 500 1000 2000 1.

Air Cleaner Element Cleaning 1 ★ or clogged Replacement 1 After cleaning 6 times or 1 year Parts Quantity Interval (hours) 8 50 100 250 500 1000 2000 1. Check Coolant Level 1 2. Check and Adjust Fan Belt Tension 1 ★★ 3. Change Coolant ZX14-3, 16-3, 18-3 2.8 L Twice a year (in spring and autumn) ZX27-3 5.3 L 4. Clean Radiator Core Outside 1 ★ Interior 1 When changing coolant