MAINTENANCE 3. Begin servicing hydraulic components only after the components, hydraulic oil and lubricants are completely cooled, and after releasing residual pressure. 3.1 Bleed air pressure from the hydraulic oil tank. 3.2 Each component, hydraulic oil, and lubricant may be hot and/or pressurized immediately after operation. Allow the machine to cool down before beginning inspection or maintenance. Failure to do so may cause burns caused by contact with hot component and/or oil, or injury by contacting flying off of plugs and /or screws. Hydraulic components may be pressurized even when cooled. Keep body parts and face away from plugs or screws and slowly loosen them.

Remove plugs and screws only after thoroughly releasing the residual pressure. 3.3 Never attempt to service or inspect the travel and swing motor circuits on slopes. Even after air pressure is released from the hydraulic oil tank, the machine on a slope will create force to pressurize hydraulic oil in the travel and swing circuit by its own weight. 1 Check Hydraulic Oil Level --- daily 1. Park the machine on a solid level surface. Position the machine with the arm cylinder fully retracted and the bucket cylinder fully extended. Lower the bucket and blade to the ground. Stop the engine. 2. Check oil level gauge (1) on the side of the hydraulic oil M1M7-05-024 tank.

Oil must be at the specified level on the gauge. 1 ZX14-3, 16-3, 18-3 M1NC-00-002 1 ZX27-3 M1NC-05-011 7-28