hitachi — Hitachi ZX14-3/ZX16-3/ZX18-3/ZX27-3 Hydraulic Excavator Operator's Manual

MAINTENANCE Drain Hydraulic Oil Tank Sump --- every 250 hours d WARNING: Be sure to work only after oil temperature 2 is low or before operation. Failure to do so may allow high temperature oil to spray, possibly causing severe burns. 1. Park the machine on a solid level surface. Position the machine with the arm cylinder fully retracted and the bucket cylinder fully extended. Lower the bucket and blade to the ground. Stop the engine. M1M7-05-024 2. Leave the machine without operating the machine until hydraulic oil becomes cool. Then, bleed air pressure from the hydraulic oil tank. 3. Slowly loosen drain plug (1) on the bottom of the hydraulic oil tank to drain water and sediment.

M1NC-07-008 1 7-29