hitachi — Hitachi ZX14-3/ZX16-3/ZX18-3/ZX27-3 Hydraulic Excavator Operator's Manual

MAINTENANCE Bleed Air from Hydraulic System After changing hydraulic oil, bleed air from the hydraulic system by following the procedure described below. Bleed Air from Pump 1 IMPORTANT: If the engine is started when the pump is not filled with hydraulic oil, damage to the pump may result. 1. Connect all hydraulic lines to the hydraulic pump. Fill the pump casing, that can be filled with clean hydraulic oil, with as much as possible. Retighten the filler plug after refilling oil. M1NC-00-002 Wrench size : 6 mm (G1/4 Hexagonal socket plug) Tightening torque : 36 to 41 N·m (3.6 to 4.1 kgf·m, 25.8 to 29.5 lbf·ft) 2. Add hydraulic oil to the hydraulic oil tank to the specified level. 3.

Check all line connections for any oil leaks. Set the engine control dial in the slow idle position. Filler Plug 4. Start the engine. Wait 5 to 10 seconds. Stop the engine. 5. Check the hydraulic oil level at the level gauge (1) located on the side of the hydraulic oil tank. Add hydraulic oil if necessary. M1NC-00-006 6. Restart the engine. Confirm that hydraulic oil level in the hydraulic oil tank is sufficient. Run the engine for approximately 1 minute. 7. This is the end of the hydraulic pump air bleeding procedure. f NOTE: If the hydraulic pump is left empty overnight or longer, be sure to fill the pump with clean hydraulic oil before performing the air bleeding procedure above.

Bleed Air from hydraulic circuits 1. After filling hydraulic oil in the hydraulic oil tank, start the engine. Evenly operate each cylinder and swing motor repeatedly for 10 to 15 minutes to purge air from hydraulic system. 2. Position the machine in the hydraulic oil level checking position. 3. Stop the engine. Check hydraulic oil level. Add oil as necessary. 7-32