hitachi — Hitachi ZX14-3/ZX16-3/ZX18-3/ZX27-3 Hydraulic Excavator Operator's Manual

MAINTENANCE E. Fuel System d WARNING: Fuel is highly flammable. Handle fuel with 1 care. Keep open flame or sparks away from fuel. Refueling After parking the machine on a level surface, check the fuel level with fuel gauge (1) and level gauge (2). When necessary to add fuel, remove fuel tank cap (3) and refill fuel. 1. To avoid condensation, fill the tank at the end of each day’s operation. Take care not to add more fuel than the specified level. M1NC-01-005 ZX14-3, 16-3, 18-3 Fuel Tank Capacity: ZX14-3, 16-3, 18-3: 22 L (5.8 US gal) 1 ZX27-3: 47 L (12.4 US gal) IMPORTANT: Take care not to allow water and/or dirt to enter the fuel system when refilling fuel. 2.

After refilling fuel, reinstall the fuel tank cap (3). Be sure to lock the fuel tank cap (3) with the key to prevent the cap from being lost as well as to prevent vandalism. M1NC-01-022 ZX27-3 Bleed Air from Fuel System Air in the fuel system will cause the engine hard to start and/or run roughly. Be sure to bleed air from the system after replacing the fuel filter or draining the tank. 3 Automatic bleeding device is provided on this machine. 2 1. Confirm that the fuel level is more than one-half of the tank capacity. If the fuel level is lower, automatic bleeding device will not operate. Add fuel. ZX14-3, 16-3, 18-3 M1NC-07-011 2. Turn the key switch ON and hold for 10 to 15 seconds. 3 3.

Start the engine and check the fuel system for fuel leaks. 2 M1NC-05-011 ZX27-3 7-44