MAINTENANCE F. Air Cleaner Clean Air Cleaner Element --- every 250 hours Replace Air Cleaner Element --- after cleaning 6 times or 1 year 1 5 1 Clean and replace air cleaner element. ZX14-3, 16-3, 18-3 1. Before servicing element (1), be sure to stop the engine. d CAUTION: Be sure to wear safety glasses or goggles M555-07-023 4 2 before removing cover (3). 2. Loosen two clamps (2) to remove cover (3) and element 2 (1). d CAUTION: Wear safety glasses or goggles when using compressed air pressure [less than 0.2 MPa (2 kgf/ cmІ, 29 psi)]. IMPORTANT: • Clean cover (3) to prevent dirt or water from entering the air cleaner suction port.

If water enters the air cleaner suction port, damage to the engine may result. • When cleaning, do not hit element (1) or force the element to collide against other object. 3 3. Clean element (3) by blowing compressed air pressure [less than 0.2 MPa (2 kgf/cmІ, 29 psi)] from the inside of the element. After cleaning, be sure to check element (1) for damage. If any damage is found, replace the element with a new one. M1NC-00-009 4 4. When installing cover (3), position the cover so that valve (4) faces downward. Then, tighten the cover with clamps (2) in the specified position. 7-49