MAINTENANCE ZX27-3 1. Before servicing element (1), be sure to stop the engine. d CAUTION: Be sure to wear safety glasses or goggles 1 5 before removing cover (3). 2. Loosen two clamps (2) to remove cover (3) and element (1). d CAUTION: Wear safety glasses or goggles when using compressed air pressure [less than 0.2 MPa (2 kgf/ cmІ, 29 psi)]. M555-07-023 4 2 from entering the air cleaner suction port. If water enters the air cleaner suction port, damage to the engine may result. • When cleaning, don’t hit element (1) or force the element to collide against other object. IMPORTANT: • Clean cover (3) to prevent dirt or water 2 3 3.
Clean element (3) by blowing compressed air pressure [less than 0.2 MPa (2 kgf/cmІ, 29 psi)] from the inside of the element. After cleaning, be sure to check element (1) for damage. If any damage is found, replace the element with a new one. 5 4. If air filter indicator (5) comes ON immediately after cleaning the element even though cleaning is less than six times, replace the element with a new one. 4 M1M7-07-041 5. When installing cover (3), position the cover so that valve ZX27-3 (4) faces downward. Then, tighten the cover with clamps (2) in the specified position. 7-50