OPERATING ENGINE Starting Engine 1 Starting in Ordinary Temperature 1. Check that pilot control shut-off lever (1) is in the LOCK position. 2. Turn engine control lever (3) to the slow idle position. 3. Sound the horn to alert bystanders. 4. Turn key switch (2) to rotate the starter. The engine will be started. IMPORTANT: Prevent starter damage and/or battery over discharge. Never run the starter for more than 10 or 15 seconds at a time (ZX14-3, 16-3, 18-3: 15 seconds, ZX27-3 : 10 seconds). If the engine fails to start, return the key switch to OFF. Wait for more than 30 seconds, then try again. 5. Release key switch (2) immediately after the engine has M1NC-05-004 started.
It will automatically return to the ON position. f NOTE: The horn sounds even though the key switch is turned 3 OFF. The engine does not start unless the pilot control shut-off lever is in the LOCK position. Fast Idle Slow Idle IMPORTANT: Avoid operating key switch (2) with stained hands or gloves. M1NC-00-007 2 M1M7-01-007 3-2