hitachi — Hitachi ZX14-3/ZX16-3/ZX18-3/ZX27-3 Hydraulic Excavator Operator's Manual

OPERATING ENGINE Using Booster Battery d WARNING: An explosive gas is produced while a battery is in use or being charged. Keep flames or sparks away from the battery area. Park the machine and booster battery machine on a dry, firm or concrete surface, not on steel plates. If the machine and/or the booster battery machine are parked on steel plates, dangerous sparks may be unexpectedly created on the machine. Never connect a positive terminal to a negative terminal, as a dangerous short circuit will occur. Connect one end of red cable (1) to the positive (+) terminal of the machine battery. 1 (Red) 2 Booster Battery Machine Battery (Black) IMPORTANT:

The machine electrical system is a 12 volt negative (-) ground. Use only 12 volt booster battery with the capacity enough to start this machine. Connect one end of black cable (2) to the upperstructure frame. M503-03-002 When the machine battery is exhausted, start the engine using a booster battery as shown below. Connecting Booster Cables 1. Stop the engine of the booster battery machine. 2. Connect one end of red cable (1) to the positive (+) terminal of the machine battery and the other end to the positive (+) terminal of the booster battery. 3.

After connecting one end of the black cable (2) to the negative (-) terminal of the booster battery, connect the other end to upperstructure frame on the machine. Be alert to sparks that may be produced in the last connection to the hydraulic oil tank cover hinge. 4. After securely connecting the booster cables, start the engine of the booster battery machine. Run the engine at a middle speed. Then, start the engine of this machine. 5. After the engine is started, disconnect booster cables (1 and 2) following the procedures below. Disconnecting Booster Cables 1. Disconnect black booster negative (-) cable (2) from upperstructure frame first. 2.

Disconnect the other end of black booster negative (-) cable (2) from the booster battery. 3. Disconnect red booster positive (+) cable (1) from the booster battery. 4. Disconnect red booster positive (+) cable (1) from the machine battery. 3-6