Komatsu — 29.6.e CHANGING THE HYDRAULIC SYSTEM FILTER ELEMENT

SCHEDULED MAINTENANCE 29.6.d CHECKING THE OIL LEVEL IN THE SWING MOTOR Check the oil level on the dipstick under filler cap (1). The level must be between the MIN and MAX marks. If necessary, top up with the recommended oil. (See section «26. FUEL, COOLANT, AND LUBRICANTS»). Use the 8 mm wrench. 1 F00221 MAX MIN 29.6.e CHANGING THE HYDRAULIC SYSTEM FILTER ELEMENT DANGER The hydraulic fluid is extremely hot when the engine has just been switched off. Wait for the engine to cool to about 40 ч 45 ° C before changing the filter. The hydraulic system is also under pressure. Unscrew the tank filler cap slowly to release residual pressure gradually.

Lubricants, filters, coolants, and batteries are special waste products and must be disposed of in compliance with local waste disposal laws. The filter is fitted to the hydraulic system return line. The filter removes all the metallic parti- cles which inevitably enter the circuit as the result of component wear. To gain access to the filter, remove the tank inspection panel. Proceed as follows to replace the filter. 1 - Remove bolts (1) securing the filter cover (2), and lift away the filter element (3) com- plete with filter body (4). Use the 13 mm wrench. 2 - Thoroughly clean out filter body (4) and check that the filter seal (6) and filter body seal (7) are in good condition. 123