SCHEDULED MAINTENANCE Always wear safety goggles and waterproof gloves when checking the battery. Do not use naked flames, do not smoke, and do not cause sparks by short- circuiting. The hydrogen gas generated by acid batteries is highly explosive. Battery electrolyte is a dangerous liquid. If you get it in your eyes or on your skin, wash the affected part thoroughly with clean running water and consult a doctor. To gain access to the battery (1), open the front right hand access panel on the revolving frame. The electrolyte level must reach about 6 mm above the plates in each cell. If necessary, top up with distilled water.
If electrolyte is spilled from the battery, diluted sul- phuric acid must be added to maintain the con- centration to suit the ambient temperatures. (See section «20.3 THE BATTERY»). 1 IMPORTANT Only add distilled water at the start of a day’s work. Weak electrolyte can freeze overnight. F00183 Check that the breather holes in the battery cell caps are not blocked when replac- ing the caps. Check that the battery terminals are not oxidised. If necessary, clean them and smear them with an anti-oxidant grease. 29.6.c CHECKING THE OIL LEVEL IN THE FINAL DRIVES This check must be repeated on both sides of the machine. The level hole must be positioned to the side of the hub to check the level.
If necessary, make small movements with the machine until the level hole is aligned perfectly along the horizontal line passing through the cen- tre of the hub. This is essential for an accurate level check. The oil level must reach hole (1). If necessary, top up with the recommended lubricant. (See section «26. FUEL, COOLANT, AND LUBRICANTS»). Use the 8 mm wrench. 1 F00285 122