Komatsu — 29.6.b CHECKING THE ELECTROLYTE LEVEL IN THE BATTERY

SCHEDULED MAINTENANCE 29.6 EVERY 250 HOURS # The following operations must be performed every 250 hours in addition to those scheduled for every 50 hours. 29.6.a ADJUSTING FAN BELT TENSION The fan belt is reached trough the upper structure after removing cover (1). Push down on the longest side of the fan belt (2) with your thumb, applying a force of about 44 N (4.5 kg). The belt should give about 10 mm. If the belt is too slack, slacken bolts (3) securing the alternator (4), place a lever between the alter- nator body and the engine block and lever the alternator outwards. Re-tighten bolts (3) and re-check fan belt tension. Use the 10 and 13 mm wrench.

1 F00846 4 3 3 10 mm 2 D00144 F00847 IMPORTANT If the fan belt is worn, replace it immediately. Check tension after a few hours when a new belt is fitted. 29.6.b CHECKING THE ELECTROLYTE LEVEL IN THE BATTERY DANGER Switch off the engine before performing this check. If the battery has to be topped up, do so at the beginning of the day’s work. 121