Komatsu — 29.9.e CHANGING THE COOLANT

SCHEDULED MAINTENANCE 29.9.e CHANGING THE COOLANT DANGER When the machine has just been stopped, the engine coolant is very hot and still under pressure, and can cause serious burns. Wait for the engine to cool to about 40 ч 45 ° C before draining the coolant. Slacken off the radiator cap slowly to release residual pressure from the tank. Lubricants, filters, coolants, and batteries are special waste products and must be disposed of in compliance with local waste disposal laws. The following operations refer to changing permanent coolant. If your cooling system is filled with water or a water and anti-freeze mix, wash out the cooling circuit to prevent it fur- ring up.

(See section «29.10.a WASHING OUT THE COOLING SYSTEM»). 1 - Unscrew the radiator cap (1) slowly and remove it. 2 - Remove the radiator drain plug (2), unscrew the drain plug (3) on the engine block and drain off all the old coolant. Use the 13 and 14 mm wrench. While the coolant is draining out, empty the coolant tank (4). 1 2 F00212 F00213 4 F00214 3 F00855 137