Kubota — Kubota D-Series Engine Manual: Safety, Maintenance, and Operation Guide

20 PERIODIC SERVICE ENGLISH AIR CLEANER Since the air cleaner employed on this engine is a dry type, never apply oil to it. 1. Open the evacuator valve once a week under ordinary conditions - or daily when used in a dusty place. This will get rid of large particles of dust and dirt. 2. Wipe the inside air cleaner clean with cloth if it is dirty or wet. 3. Avoid touching the element except when cleaning. 4. When dry dust adheres to the element, blow compressed air from the inside turning the element. Pressure of compressed air must be under 205kPa (2.1kgf/cm 2 , 30psi). 5.

When carbon or oil adheres to the element, soak the element in detergent for 15 minutes, then wash it several times in water, rinse with clean water and dry it naturally. 6. After the element is fully dried, inspect the inside of the element with a light, and check if it is damaged or not. (referring to the instructions on the label attached to the element.) 7. Replace the element every year or every 6 cleanings. B Evacuator valve Open the evacuator valve once a week under ordinary conditions - or daily when used in a dusty place - to get rid of large particles of dust and dirt.

B Dust indicator (optional) If the red signal on the dust indicator attached to the air cleaner is visible, the air cleaner has reached the service level. Clean the element immediately, and reset the signal with the "RESET" button. (1) "RESET" button (2) Dust indicator (3) Service level (4) Signal (1) Air cleaner body (2) Element (3) Wing bolt (4) Evacuator valve A Make sure the wing bolt for the element is tight enough. If it is loose, dust and dirt may be sucked in, wearing down the cylinder liner and piston ring earlier, and thereby resulting in poor power output. A Do not overservice the air cleaner element. Overservicing may cause dirt to enter the engine causing premature wear.

Use the dust indicator as a guide on when to service.