Yamaha Grizzly 660 — Yamaha Grizzly 660 User Manual

CHECKING THE BATTERY Relationship between the open-circuit voltage and the charging time at 20 °C Check the condition of the battery using the following charts. Example: Open-circuit voltage (V) Open-circuit voltage = 12.0 V Charging time = 6.5 hours Charge condition of the battery = 20 ~ 30% Charging method for MF batteries These values vary with the temperature, the condition of the battery plates, and the electrolyte level. Charging time (hours) CAUTION: If it is impossible to set the standard charging current, be careful not to over- charge. Charging Ambient temperature 20 °C Open-circuit voltage (V) When charging the battery, be sure to remove it from the motorcycle.

(If charg- ing has to be done with the battery mounted on the motorcycle, be sure to disconnect the wire at the negative termi- nal.) Time (minutes) Never remove the sealing caps of an MF battery. Check the open-circuit voltage. Make sure that the charging clips are in full contact with the terminal and that they are not shorted together. (A corroded clip on the charger may cause the battery to generate heat in the contact area. A weak clip spring may cause sparks.) Open-circuit voltage (V) Ambient temperature 20 °C Before removing the clips from the bat- tery terminals, be sure to turn off the charger’s power switch.

Charging condition of the battery (%) The open-circuit voltage variation for the MF battery, after charging, is shown below. As shown in the figure, the open- circuit voltage stabilizes about 30 min- utes after charging has been completed. Therefore, wait 30 minutes after charging is completed before measuring the open- circuit voltage. 3 - 60 CHK ADJ CHK ADJ