CHECKING THE CONDITION OF THE BULB SOCKETS The following procedure applies to all of the bulb sockets. 1.Check: Bulb socket (for continuity) (with the pocket tester) No continuity Replace. NOTE: Check each bulb socket for continuity in the same manner as described in the bulb section; however, note the following. ***************************************************** a.Install a good bulb into the bulb socket. b.Connect the pocket tester probes to the respective leads of the bulb socket. c.Check the bulb socket for continuity. If any of the readings indicate no continuity, replace the bulb socket.
***************************************************** CHECKING THE LEDs The following procedure applies to all of the LEDs. 1.Check: LED (for proper operation) ***************************************************** a.Disconnect the meter assembly coupler (meter assembly side). b.Connect two jumper leads from the battery terminals to the respective coupler terminals as shown. WARNING A wire that is used as a jumper lead must have at least the same capacity of the bat- tery lead, otherwise the jumper lead may burn. This check is likely to produce sparks, therefore make sure that no flammable gas or fluid is in the vicinity.
c.When the jumper leads are connected to the terminals the respective LED should illuminate. Does not light Replace the meter assem- bly. 9 - 8 ***************************************************** CHECKING THE BULBS AND BULB SOCKETS ELEC – + Pocket tester: P/N. YU-03112, 90890-03112